ST1 (FX)
FX-230 F75 T F/F
Order number: A03392F connectors, 75 ohm
- lightning current arrested with floating shielding (separated with GDT)
- installation at the boundary of LPZ 0 and LPZ 1 zones at the line entry into building
- for protection of coaxial lines of TV and CCTV systems, suitable as the 1st level of surge for protection in coordination with the SX type
- in the scope of delivery: universal plastic adapter for mounting on DIN rail and GND 2 holder
Technical parameters
| Parameter name | Parameter value | |
|---|---|---|
| Type of SPD | D1,C2 | |
| Location of SPD | ST 1 | |
| Mounting | DIN rail 35 mm | |
| Maximum operating voltage | Uc | 180.00 V DC |
| Nominal load current | IL | 4.000 A |
| Frequency range | f | 0,00 - 2150,00 MHz |
| Impedance | Z | 75 Ω |
| Insertion loss | 0.20 dB | |
| VSWR typ. (max.) | VSWR | 1,3 |
| D1 impulse discharge current (10/350 µs) SH-PE | Iimp | 2.50 kA |
| D1 impulse discharge current (10/350 µs) core-SH | Iimp | 2.50 kA |
| C2 nominal discharge current (8/20 µs) SH-PE | In | 10.00 kA |
| C2 nominal discharge current (8/20 µs) core-SH | In | 10.00 kA |
| C3 voltage protection level mode SH-PE at 1 kV/µs | Up | 660 V |
| C3 voltage protection level mode core-SH at 1 kV/µs | Up | 660 V |
| Response time core-SH | ta | 100 ns |
| Response time SH-PE | ta | 100 ns |
| Connection (input - output) | F 75 | |
| Degree of protection | IP 20 | |
| Range of ambient temperatures (min/max) | -40 / 80 °C | |
| According to standard | EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012 | |
| ETIM Class | EC001466 | |
| Customs tariff number | 85363010 | |
| EAN | 8595090533924 |