FLP-25-T1-VS/3

FLP-25-T1-VS/3

Describe first line
pluggable module, visual fault signalling, module locking, remote fault signalling
Product description
  • three-pole high performance lightning current arrester, leakage current-free
  • installation at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution boards
  • for protection against impact of direct or indirect lightning strikes in wide range of applications – houses, office and industrial buildings
  • coordination with SPD type 2 (SLP-275 V) even without surge separating inductors
Ordering number
A05301
Dimension drawing
Basic circuit diagram
Technical specifications
Type of SPD
T1
Nominal voltage
Un
230
V AC
Maximum operating voltage
Uc
260,00
V AC
Nominal load current for "V" connection
IL
125
A
Lightning impulse current (10/350 µs)
Iimp
25,00
kA
Total discharge current (10/350 µs)
ITotal(10/350)
75,00
kA
Voltage protection level
Up
1,50
kV
Short-circuit current rating
ISCCR
50,0
kA
Maximum overcurrent protection
250 A gL/gG
Maximum overcurrent protection for "V" connection
125 A gL/gG
Response time
ta
100
ns
TOV 5 s L-N
335
V
TOV characteristic (TOV 5 s)
withstand
Cross-section of connected conductors solid (min)
2,50
mm2
Cross-section of connected conductors solid (max)
50,00
mm2
Cross-section of connected conductors stranded (min)
2,50
mm2
Cross-section of connected conductors stranded (max)
35,00
mm2
Fault indication
red indication field
Remote indication
potential-free change-over contact
Remote indication contacts
250V/0,5A AC,250V/0,1A DC
Cross-section of remote indication conductors
1,5
mm2
Degree of protection
IP 20
Range of ambient temperatures - min
-40
°C
Range of ambient temperatures - max
80
°C
Mounting
DIN rail 35 mm
According to standard
EN 61643-11:2012, IEC 61643-11:2011
Plug module
FLP-25-T1-V/0
ETIM Class
EC000381
Customs tariff number
85363090
EAN
8595090553014

Other products in this category

Ordering number:
A06263
  • combined lightning current arrester, suitable for TN and TT systems, installation at the line entry into building
  • 25 kA (10/350)
Ordering number:
A06257
  • combined lightning current arrester, suitable for 1-phase TT systems, installation at the line entry into building
  • 50 kA (10/350)
Ordering number:
A06259
  • combined lightning current arrester, suitable for 1-phase TN-S systems, installation at the line entry into building
  • 50 kA (10/350)
Ordering number:
A05300
  • lightning current arrester for 3-phase TN-C system, installation at the entry into building
  • 75 kA (10/350 µs)
  •  
  • 1 of 3
  • >