FLP-25-T1-VS/2



FLP-25-T1-VS/2

Describe first line 
pluggable module, visual fault signalling, module locking, remote fault signalling
Product description 
two-pole high performance lightning current arrester without follow current, installation at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution boards, for protection against impact of director or indirect lightning strikes in wide range of applications – houses, office and industrial buildings, coordination with SPD type 2 (SLP-275 V) even without surge separating inductors, no leakage current, remote fault signalling
Ordering number 
A06260
Dimension drawing
Basic circuit diagram
Technical specifications
Type of SPD 
T1
Nominal voltage 
Un
230
V AC
Maximum operating voltage 
Uc
260,00
V AC
Nominal load current for "V" connection 
IL
125
A
Lightning impulse current (10/350 µs) 
Iimp
25,00
kA
Total discharge current (10/350 µs) 
ITotal(10/350)
50,00
kA
Voltage protection level 
Up
1,50
kV
Short-circuit current rating 
ISCCR
50,0
kA
Maximum overcurrent protection 
250 A gL/gG
Maximum overcurrent protection for "V" connection 
125 A gL/gG
Response time 
ta
100
ns
TOV 5 s L-N 
335
V
TOV characteristic (TOV 5 s) 
withstand
Cross-section of connected conductors solid (min) 
2,50
mm2
Cross-section of connected conductors solid (max) 
50,00
mm2
Cross-section of connected conductors stranded (min) 
2,50
mm2
Cross-section of connected conductors stranded (max) 
35,00
mm2
Fault indication 
red indication field
Remote indication 
potential-free change-over contact
Remote indication contacts 
250V/0,5A AC,250V/0,1A DC
Cross-section of remote indication conductors 
1,5
mm2
Degree of protection 
IP 20
Range of ambient temperatures - min 
-40
°C
Range of ambient temperatures - max 
80
°C
Mounting 
DIN rail 35 mm
According to standard 
EN 61643-11:2012, IEC 61643-11:2011
Plug module 
FLP-25-T1-V/0
ETIM Class 
EC000381
Customs tariff number 
85363090
EAN 
8595090562603

Other products in this category

Ordering number:
A06263
combined lightning current arrester, suitable for TN and TT systems, installation at the line entry into building, 25 kA (10/350)
Ordering number:
A06257
combined lightning current arrester, suitable for 1-phase TT systems, installation at the line entry into building, 50 kA (10/350)
Ordering number:
A06259
combined lightning current arrester, suitable for 1-phase TN-S systems, installation at the line entry into building, 50 kA (10/350)
Ordering number:
A05300
lightning current arrester for 3-phase TN-C system, installation at the entry into building, 75 kA (10/350 µs)
  •  
  • 1 of 3
  • >